Mechanical values and environment | |
---|---|
Housing material | Reinforced thermoplastic |
Weight | |
Net | 0,5 kg |
Ambient temperature | -20 ... 50 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation position | Any |
Number of door position positively driven contacts | 3 |
Number of guard lock monitoring NC contacts | 2 |
Connection | Connection cable 5m |
Approach speed | 0,05 ... 1 m/min |
Actuation frequency | 900 1/h |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 500 N |
Retention force | 1 N |
Extraction force | 10 N |
Actuating force | 5 N |
Insertion depth | 26,3 mm |
Electrical connection ratings | |
Rated thermal current Ith | 2,5 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 0.75A 250V 1A 125V |
DC-13 | 0.27A 250V 0.22A 125V |
Solenoid operating voltage | |
DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 2A gG |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 2,7 W |
Solenoid duty cycle | 100 % |
Reliability values acc. to EN ISO 13849-1 | |
Monitoring of the position of the safety guard | |
B10D | 2 x 106 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
in combination withActuator BETAETIGER-Q-GT, RADIUSBETAETIGER-Q-RO, RADIUSBETAETIGER-Q-LU, BETAETIGER-Q-WT | |
Overtravel A B C D E | 1,9 mm |
in combination withActuator BETAETIGER-Q-WTB | |
Overtravel A B C D E | 1,3 mm |
8 (029) 555-8-000 | |
<img alt="" src="https://images.by.prom.st/161381611_161381611.jpg?PIM</h3> |